Streamline 413MCS07V

Solahart 410L Solar Split System | LCS Collector for High Demand Homes

The Solahart 413MCS07V features a 410-Litre tank and three LCS collectors to deliver energy-efficient solar hot water for up to 7 people.

6-7
Family size
410L
Capacity
3
Collectors
5/3/2Years
Warranty

Streamline 413MCS07V: Key Attributes

 

The Solahart 413MCS07V is a powerful split system solar water heater built for large families or high-demand homes. It pairs a spacious 410-Litre ground-mounted tank with three high-efficiency LCS collectors, making it suitable for up to seven people.

Designed for Australia’s cooler regions, this system includes frost protection and can be safely installed up to 600 metres in elevation. Like all MDV models, it is not intended for use in areas with harsh water conditions. Backed by Solahart’s 5-year tank warranty, the 413MCS07V is a dependable, eco-friendly solution for large households.

Key Features / USPs:

  • 410L tank for large families (up to 7 people)
  • LCS solar collector for strong performance
  • Enhanced frost protection for cold regions
  • Altitude rated up to 600m
  • Reduce energy consumption by up to 70%*
  • Backed by Solahart's 5-year tank warranty
  • Not suitable for poor water conditions^
  • Specifications
    Solar Storage Tank
    Storage Capacity (litres) 410
    Boost Capacity (Electric) (litres) 220
    Installation Indoor/Outdoor
    Solar Controller Kit PN 299293
    Weight Empty (kg) 115
    Weight Full (kg) 531
    Height (m) 1.840
    Width (m) 0.690
    Depth (m) 0.730
    Electric Boost Specifications
    Heating Unit Type Cooper sheath immersion element
    Supply Voltage 240V 50hz
    Collectors General
    Aperture (heating) Area (m2) 1.87
    Length (mm) 1996
    Width (mm) 1043
    Height (mm) 82
    Capacity (litres) 1.2
    Working Pressure 1000 kPa
    CSA2007 Collectors
    Weight Emtpy (kg) 36
    Weight Full (kg) 41
    Absorber Surface Blue Tinox sputtered selective
    Absorber Material copper
    Riser Material copper tube
    Tray Material extruded aluminium frame with 0.40mm Zincalume backing sheet
    Insulation Material - Base 38mm glass wool blanket
    Glass 3.2mm tempered low iron glass
    Water Supply
    TPR Valve Setting 1000 kPa
    145 psi
    ECV* Setting 850 kPa
    125 psi
    Max. Supply Pressure With ECV 680 kPa
    Max. Supply Pressure Without ECV 800 kPa
    Minimum Supply Pressure 200 kPa / 29 psi
    Water Connections Cold Rp 3/4
    Water Connections Hot Rp 3/4
    Water Connections Solar DN15 compression fittings (solar hot and solar cold inlets to tank Rp 3/4)

    * The suggested price is comprised of RRP less the applicable solar incentive and excluding installation. Solar incentive value applies to 413MCS07V system in Zone 3.
    ^ Energy savings of up to 75% shown are based on Australian Government approved TRNSYS simulation modelling of a Solahart 413CS07V and using a large load in Zone 3 and apply when replacing an electric water heater. Any savings will vary depending upon your location, type of Solahart system installed, orientation and inclination of the solar collectors, type of water heater being replaced, hot water consumption and fuel tariff. Maximum financial savings off your hot water bill are achievable when replacing an electric water heater on continuous tariff.
    † Solahart Warranty Details: 5/3/2 warranty; 5 year cylinder and collectors supply, 3 year parts, 2 year labour; applies to a single family domestic dwelling only. Without limiting these periods, a 5-year whole-of-product warranty applies where a rebate has been received under Solar Victoria’s Solar Homes Program for installations from 1st July 2023. For further details, call 131 031.
All other applications have a 3/1/1 warranty; 3 year cylinder and collector supply, 1 year parts supply, 1 year labour.

  • How it works

    How Split System Solar Water Heaters Work

    With open circuit split systems the water is circulated from the tank at ground level through the solar collectors by an electric pump called a 'circulator'. As the sun heats the water in the solar collectors, the increase in temperature activates the circulator. The circulator switches on whenever the water in the solar collectors is hotter than the water in the solar storage tank. The circulator moves the hotter water from the solar collectors through the solar hot pipe to the solar storage tank and the cooler water from the solar storage tank is circulated to the solar collectors via the solar cold pipe to be heated by the sun’s energy. This process continues whilst solar energy is available and the water in the solar storage tank requires heating. The circulator will deactivate when the water temperature in the solar storage tank is around 70°C to 75°C.

    The Solahart 413MCS07V split solar water heater is designed to be installed as an electric boosted solar water heater with its booster heating unit connected to a power supply, however it may be installed with an in-series continuous flow or storage booster. If installed with an in-series booster, then the electric booster heating unit will not be connected to a power supply.

    Solar Operation

    The operation of the circulator is controlled by the combination of:

    • the hot sensor located at the outlet of the solar collectors. The hot sensor measures the water temperature at the outlet of the solar collectors.
    • the cold sensor located at the solar cold outlet at the base of the solar storage tank. The cold sensor measures the water temperature at the bottom of the solar storage tank.
    • the differential controller located in the solar control unit.

    With open circuit split systems, the water is circulated from the tank at ground level through the solar collectors by an electric pump called a 'circulator'. As the sun heats the water in the solar collectors, the increase in temperature activates the circulator. The circulator switches on whenever the water in the solar collectors is hotter than the water in the solar storage tank. The circulator moves the hotter water from the solar collectors through the solar hot pipe to the solar storage tank and the cooler water from the solar storage tank is circulated to the solar collectors via the solar cold pipe to be heated by the sun’s energy.

    This process continues whilst solar energy is available and the water in the solar storage tank requires heating. The circulator will deactivate when the water temperature in the solar storage tank is around 70°C to 75°C.

    During normal operation if the amount of solar energy available reduces, such as when the sky becomes very cloudy or the sun becomes lower in the sky in the late afternoon, and the water no longer gains usable heat from the solar collectors, the circulator will deactivate. The water heater will then enter standby mode.

    Over-Temperature Operation

    The purpose of the Over-temperature operation is to reduce the amount of overheating or ‘stagnation’ of water in the solar collectors. When the water in the solar storage tank has reached 70°C to 75°C and the circulator has deactivated, the solar collectors will continue to gain heat while solar energy is still available.

    If the water in the solar collectors stagnates and its temperature becomes very high, the circulator will activate for a short period to transfer this extra energy to the solar storage tank. The circulator will deactivate when the water temperature in the solar collectors decreases. This process will either repeat for a maximum of eight cycles or until the water temperature in the solar storage tank reaches around 75°C to 80°C or the hot sensor does not sense another increase in water temperature to a stagnation level after a cycle is completed, i.e. the solar energy available reduces.

    Night Time Cooling Operation

    The purpose of Night Time Cooling operation is to rid the solar storage tank of excess solar energy gained by Over-temperature operation during that day. The desired water temperature in the solar storage tank is to be between 60°C to 70°C.

    If the solar control unit has entered Over-temperature operation during the day, then after the water temperature in the solar collectors reduces later in the day or early evening, the circulator will activate. Water from the solar storage tank will circulate through the solar collectors and excess heat in the water will radiate from the solar collectors reducing the temperature of the water. The water will circulate for a period of time and until the water temperature in the solar storage tank is around 60°C to 70°C. The water heater will then enter standby mode.

    Freeze Protection Operation

    The purpose of Freeze Protection operation is to prevent freezing of water in the solar collectors and solar pipe work in very cold conditions. The water in the solar collectors will cool during periods of no solar gain. In very cold conditions, such as overnight and very early in the morning before sunrise, the water temperature can approach freezing point.

    If the hot sensor measures that the water temperature in the solar collectors is approaching freezing, the circulator will activate. Water from the solar storage tank, containing more energy than the water in the solar collectors, will circulate through the solar collectors keeping the water temperature above freezing point. The circulator will remain on for some minutes and until the hot sensor measures a water temperature at a safe level above freezing. When both of these conditions are met, the circulator will deactivate. The water heater will then enter standby mode.

    Standby Mode

    The water heater will be in Standby mode whenever conditions are not favourable for solar heating in Normal operation, and Over-temperature operation and Night Time Cooling are not required or have been completed, and conditions are not cold enough for or in-between Freeze Protection operation.

  • Downloads